Related Topics:
Facility ID: 14304THGDY5408B
Facility Name and Address: GOODYEAR TIRE & RUBBER CO 5500 GOODYEAR DR NIAGARA FALLS, NY 14304 Parent Company: THE GOODYEAR TIRE & RUBBER CO Industry: All Other Basic Organic Chemical Manufacturing (325199) Chemical: Diphenylamine Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=0000122394
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Display facility comparison report for this parent company
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2022 |
Source Reduction:: S34: Improved monitoring practices of potential spill or leak sources
|
Methods to Identify SR Opportunities: T11: Other
|
S34: Goodyear annually performs a thermographic inspection of the solvent systems to identify any potential fugitive emissions leaks that may be occurring. In addition to the thermographic survey, a thorough visual inspection was performed on all accessible threaded joints looking for signs of leaking. Any potential leaks or areas of damage were repaired. Source Reduction - Thermographic survey and visual inspection |
2021 |
Source Reduction:: S34: Improved monitoring practices of potential spill or leak sources
|
Methods to Identify SR Opportunities: T11: Other
|
S34: Goodyear annually performs a thermographic inspection of the solvent systems to identify any potential fugitive emissions leaks that may be occurring. In addition to the thermography survey, a thorough visual inspection was performed on all accessible threaded joints looking for signs of leaking. Any potential leaks or areas of damage were repaired. Source Reduction - Thermography survey and visual inspection |
2020 |
Source Reduction:: W36: Implemented inspection or monitoring program of potential spill or leak sources
|
Methods to Identify SR Opportunities: T11: Other
|
W36: Goodyear annually performs a thermographic inspection of the solvent systems to identify any potential fugitive emissions leaks that may be occurring. In addition to the thermography survey, a thorough visual inspection was performed on all accessible threaded joints looking for signs of leaking. Any potential leaks or areas of damage were repaired. Source Reduction - Thermography survey and visual inspection |
2019 |
Source Reduction:: W50: Optimized reaction conditions or otherwise increased efficiency of synthesis
|
Methods to Identify SR Opportunities: T11: Other
|
W50: In 2019 compared to 2018 the reaction formulation was changed to increase the batch cycle time which increased the yield of batches. The formulation change also reduced the amount of unreacted raw materials that would normally be transferred off-site for energy recovery |
2018 |
Source Reduction:: W19: Other changes in operating practices
|
Methods to Identify SR Opportunities: T11: Other
|
W19: Improved heating system of the outdoor storage tanks to reduce the quantity of sludge formation. Sludge formed in the outdoor storage tanks is discharged as hazardous waste. |
2017 |
Source Reduction:: W52: Modified equipment, layout, or piping[-0-4%]
|
Methods to Identify SR Opportunities: T04: Participative team management
|
W52: Tank clean out material from the deluge tower was drummed and transported off site for disposal. A new procedure was put in place to reduce waste by pumping the liquid to the solvent recovery process and recovering the raw material to use as a reactant in the manufacturing process. |
2016 |
Source Reduction:: W52: Modified equipment, layout, or piping[-0-4%]
|
Methods to Identify SR Opportunities: T04: Participative team management
|
W52: Reduced threaded piping connections and installed welded flanges. Replaced sample collection boxes with larger and more ergonomic design to eliminate spillage when using gloves and operating valves inside the vented sample collection box. |
2015 |
Source Reduction:: W39: Other spill or leak prevention[-0-4%]
Source Reduction:: W52: Modified equipment, layout, or piping[-0-4%] Source Reduction:: W56: Reduced or eliminated use of an organic solvent[-0-4%] |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management |
W39: Changed out threaded pipe connections in organic service to welded flanged connections. W52: Upgraded control valves to Enviro Seal packing to reduce fugitive emissions from the valve stem. Upgraded carbon steel piping in corrosive service to Hastelloy C. W56: Substituted city water for neutralization make up from organic water. This substitution eliminated organic emissions from U-32017 |
2014 |
Source Reduction:: W51: Instituted recirculation within a process
Source Reduction:: W71: Other cleaning and degreasing modifications |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T04: Participative team management |
Source Reduction - Increased recovery of organics in process water from the Sump Holding tank by using the Solvent Recovery Process. Source Reduction - -Improved cleaning operation of Tri-Mer scrubber mist eliminators. Source Reduction - W71: Improved cleaning operation at Tri-Mer Scrubber mist eliminators W51: Increased recovery of organics in process water from the Sump Holding tank by using the Solvent Recovery Process. |
2013 |
Source Reduction:: W13: Improved maintenance scheduling, recordkeeping, or procedures
|
Methods to Identify SR Opportunities: T10: Vendor assistance
|
W13: Mechanical Integrity files were reorganized for improved record keeping. Source Reduction - Contracted employees helped with the new system of record keeping and retention of inspections. |
2011 | Source Reduction - Prcess control and process effciency | ||
2010 | Source Reduction - Process control and process efficiency |