Facility Name and Address: B. BRAUN MEDICAL INC MANUFACTURING DIV 901 MARCON BLVD ALLENTOWN, PA 18109 Parent Company: B BRAUN MEDICAL INC Industry: Surgical and Medical Instrument Manufacturing (339112) Chemical: Ethylene oxide Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=0000075218
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Display facility comparison report for this parent company
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2022 |
Source Reduction: Source Reduction - In 2020, a new emission control device was voluntarily installed for improved ethylene oxide destruction efficiency. The new control device does not produce Ethylene Glycol as a byproduct. |
||
2021 | |||
2020 |
Source Reduction: Source Reduction - In 2020, a new emission control device was voluntarily installed for improved ethylene oxide destruction efficiency. |
||
2019 |
Source Reduction:: W58: Other process modifications
|
Methods to Identify SR Opportunities: T04: Participative team management
|
W58: Additional air emission control device voluntarily installed and operated. |
2017 |
Source Reduction:: W19: Other changes in operating practices
|
Methods to Identify SR Opportunities: T11: Other
|
W19: Operation went from 24/7 to 24/5 in April of 2016. When this change occurred the amount of ethylene oxide purchased and consumed decreased. Contract sterilization was also utilized during this time period. |
2016 |
Source Reduction:: W19: Other changes in operating practices
|
Methods to Identify SR Opportunities: T11: Other
|
W19: Effective May 2016, product from other B. Braun facilities are no longer being sterilized at Allentown Operations. This has resulted in the 46% decrease in ethylene oxide used on site. Source Reduction - See above |