Related Topics:
Facility ID: 42029CLNSL408NM
Facility Name and Address: SEKISUI SPECIALTY CHEMICALS AMERICA LLC 246 JOHNSON RILEY ROAD CALVERT CITY, KY 42029 Parent Company: SEKISUI AMERICA CORP Industry: Plastics Material and Resin Manufacturing (325211) Chemical: Vinyl acetate Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=0000108054
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Display facility comparison report for this parent company
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2017 | Other Environmental Practices - Evaluating ways to reduce | ||
2016 |
Barriers: B7-Barriers to P2 B7 - No known substitutes or alternative technologies.
|
Barriers to P2: B7 - No known substitutes or alternative technologies. - Evaluating ways to reduce. |
|
2013 |
Source Reduction:: W52: Modified equipment, layout, or piping
|
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
|
W52: Six mechanical seals on the polykettles (reactors) were upgraded to reduce fugitive emissions from equipment leaks. Source Reduction - An opportunity to reduce fugitive equipment leak emissions from the polykettles was identified by the maintenance department and engineering group. Source Reduction - The design of the mechanical seals on the top of six polykettles was upgraded to a design specific for agitator service. The conventional design was originally a pump seal adapted to agitator service. The upgraded configuration is designed to tolerate shaft movement, and this has increased the reliability of the new seal This has resulted in the reduction of vinyl acetate fugitive emissions. |
2009 |
Source Reduction:: W39: Other spill or leak prevention
Source Reduction:: W52: Modified equipment, layout, or piping |
Methods to Identify SR Opportunities: T11: Other
Methods to Identify SR Opportunities: T11: Other |
Source Reduction - FACILITY ROUTED EMISSIONS FROM THE POLYMERIZATION LINE REACTORS, PASTE TANKS, AND VINYL ACETATE REWORK TANKS TO THE FLARE AND CONTINUED A LEAK DETECTION AND REPAIR (LDAR) PROGRAM IN THE POYMERIZTION AND POLYRECTIFICATION PROCESS AREAS AS REQUIRED BY 40 CFR 63 SUBPART FFFF FOR MISCELLANEOUS ORGANIC CHEMICAL MANUFACTURING (MON). |
2008 |
Source Reduction:: W39: Other spill or leak prevention
Source Reduction:: W52: Modified equipment, layout, or piping |
Methods to Identify SR Opportunities: T11: Other
Methods to Identify SR Opportunities: T11: Other |
Source Reduction - Facility routed emissions from the Polymerization Line Reactors, Paste Tanks, and Vinyl Acetate Rework Tanks to the flare and implemented a leak detection and repair (LDAR) program in the Polymerization and Polyrectification process areas as required by 40 CFR 63 Subpart FFFF for Miscellaneous Organic Chemical Manufacturing (MON). |