Related Topics:
Facility ID: 44111BRTPL3000W
Facility Name and Address: PLASMAN CLEVELAND MANUFACTURING 3000 W 121ST ST CLEVELAND, OH 44111 Parent Company: NA Industry: Electroplating, Plating, Polishing, Anodizing, and Coloring (332813) Chemical: Nickel Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=0007440020
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2018 |
Source Reduction:: W58: Other process modifications[-5-14%]
|
Methods to Identify SR Opportunities: T03: Materials balance audits
|
W58: Nickel recover unit was installed which reuses nickel as nickel sulfate and nickel chloride. The unit can recover up to 800 lb/day of NiSO4 and NiCl2. Source Reduction - By tracking the amount of NiSO4 and NiCl2 purchased, calculating the concentrations of Ni in final effluent going to POTW and in sludge for recycling we can determine the efficiency of the Nickel recovery unit. |
2017 |
Source Reduction:: W58: Other process modifications[-15-24%]
|
Methods to Identify SR Opportunities: T03: Materials balance audits
|
W58: Installed a Nickel recovery unit. The unit Reuse Nickel as Nickel Sulfate or Nickel Chloride in Semi-Bright or Bright Nickel Bath. Can recover up to 800lb/day NiSO4. Source Reduction - By tracking the purchased amount of NiSO4 and NiCl , calculating the concentrations of Ni in final effluent going to POTW and in sludge for recycling we can determine the efficiency of our Nickel recovery unit. |