Related Topics:
Facility ID: 64116NTNLS1001B
Facility Name and Address: INGREDION INC 1001 BEDFORD AVE NORTH KANSAS CITY, MO 64116 Parent Company: INGREDION INC Industry: Wet Corn Milling (311221) Chemical: Propylene oxide Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=0000075569
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Display facility comparison report for this parent company
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2019 |
Other Barriers to Source Reduction - Control devises especially thermal oxidation would require massive fuel use just to remove 8360 lbs. of propylene oxide. |
||
2017 |
Other Environmental Practices: Recycling - We went to single stream recycling in 2017 Other Environmental Practices: General Environmental Management - We are now requiring each member of the plant leadership team to conduct at least 1 environmental observation each month. Source Reduction: Methods for Identifying Pollution Prevention Opportunities - We have a revamped SPCC and SWPPP plan. We are requiring environmental observations. |
||
2016 |
Source Reduction:: W52: Modified equipment, layout, or piping
|
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
|
W52: performed pipe thickness testing of PO piping and replaced some sections of pipe. |
2015 |
Barriers: B6-Barriers to P2 B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas
|
Barriers to P2: B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas - We have in the past installed PPM monitors in the areas of PO usage. These monitors activate whenever a leak occurs. This allows the process to be corrected before large amounts of the PO can be released. |
|
2013 |
Source Reduction:: W36: Implemented inspection or monitoring program of potential spill or leak sources
|
Methods to Identify SR Opportunities: T10: Vendor assistance
|
Source Reduction - PPM meters were installed in the group 3 reaction areas. This allow for a much lower detection limit as opposes to LEL which is in percent. Leakage can be detected all the way down to 1 ppm. |
2005 |
Source Reduction:: W32: Improved procedures for loading, unloading, and transfer operations
Source Reduction:: W39: Other spill or leak prevention Source Reduction:: W52: Modified equipment, layout, or piping |
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s) Methods to Identify SR Opportunities: T11: Other |