Related Topics:
Facility ID: 80401DLPHC12THF
Facility Name and Address: MOLSON COORS USA LLC - GOLDEN BREWERY 12TH & FORD STREETS GOLDEN, CO 80401 Parent Company: MOLSON COORS BEVERAGE CO Industry: Breweries (312120) Chemical: Ammonia Reports: View TRI Facility profile report for this facility View TRI Form R submissions by this facility |
|
*You can navigate within the map with your mouse. |
Production Related Waste Management for Selected Chemical
lchemid=007664417
Chart Options1: |
Waste Management Comparison -
Display facility comparison report for this industry and chemical
Display facility comparison report for this parent company
Pollution Prevention Activities for Selected Chemical
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2016 |
Source Reduction:: W52: Modified equipment, layout, or piping[-0-4%]
|
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s) |
W52: Reduced footprint and quantity of on site quantity. Source Reduction: Source Reduction - With reduction in ammonia system footprint, the source of the releases is also reduced. Other Environmental Practices: General Environmental Management - The MillerCoors Energy and Water reduction programs drive many improvements and reduction in risk of releases. Other Environmental Practices: Energy Recovery - Reduction in footprint and refrigeration requirements also reduces energy usage. Other Environmental Practices: Recycling - Ammonia in waste water sludge is recycled through composting operations. |
2015 |
Source Reduction:: W58: Other process modifications[-0-4%]
|
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
Methods to Identify SR Opportunities: T02: External pollution prevention opportunity audit(s) |
Source Reduction - Reducing the amount of ammonia used in refrigeration. Source Reduction - Converting to Urea from ammonia for nutrient addition at waste water treatment. Source Reduction: Source Reduction - The MillerCoors Golden Brewery is continuously implementing process modifications to reduce the amount of ammonia on site. Other Environmental Practices: Waste Treatment - Conversion from ammonia as a nutrient to urea as a nutrient. |
2014 |
Source Reduction:: W36: Implemented inspection or monitoring program of potential spill or leak sources[-0-4%]
Source Reduction:: W52: Modified equipment, layout, or piping[-0-4%] Source Reduction:: W58: Other process modifications[-0-4%] |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s) |
W52: Reduced inventory resulting in cutting and capping obsolete equipment. W58: Converted to Urea reducing requirement for ammonia as a nutrient for waste water treatment operations. Source Reduction - Teams identify equipment to be cut and capped, perform change, modify procedures and maintenance requirements. |
2013 |
Source Reduction:: W58: Other process modifications
|
Methods to Identify SR Opportunities: T04: Participative team management
|
W58: Reduction in the required refrigeration allows reduction in chemical inventory at the facilaity. |
2012 |
Source Reduction:: W42: Substituted raw materials
Source Reduction:: W52: Modified equipment, layout, or piping |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s) Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program) |
W42: Substituted Urea for Ammonia for nutrient feed to waste water treatment plant W52: Have reduced the amount of equipment required for refrigteration. Therefore, have shut it down and isolated it. Source Reduction - participative managment implemented the change Source Reduction - This was initiated by internal reviews of the ammonia system. Source Reduction - portions of the change was related to employee recommendations. |
2005 |
Source Reduction:: W58: Other process modifications
|
Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program)
|
Source Reduction - Replaced anhydroun ammonia with urea for water treatment at the WWTP. |