Facility ID: 33710MLXTC23757
Facility Name and Address: MOLEX LLC 2375 72ND ST N SAINT PETERSBURG, FL 33710 Parent Company: KOCH INDUSTRIES INC Industry: Electronic Connector Manufacturing (334417) Chemical: Copper |
|
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2022 |
Source Reduction:: S21: Optimized process conditions to increase efficiency[-0-4%]
|
Methods to Identify SR Opportunities: T10: Vendor assistance
|
S21: Purchased more efficient Sludge Press |
2021 |
Barriers: B6-Barriers to P2 B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas
|
Barriers to P2: B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas - Waste generation is production dependent |
|
2020 |
Source Reduction: Source Reduction - Removed Boiler so eliminated Boiler Blowdown |
||
2019 |
Source Reduction:: W59: Modified stripping/cleaning equipment
|
Methods to Identify SR Opportunities: T11: Other
Methods to Identify SR Opportunities: T10: Vendor assistance Methods to Identify SR Opportunities: T04: Participative team management |
Source Reduction - Reduced Waste water by source improvements pre-filtering water and increased equipment efficiency Other Environmental Practices: General Environmental Management - ISO 14001 System |
2018 |
Source Reduction:: W68: Improved rinse equipment operation[-0-4%]
|
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T11: Other Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program) |
W68: Installed Plate line water reuse Source Reduction - ISO14001 Driven Source Reduction - ISO14001 Management Driven Source Reduction - Internal Reduction Target Other Environmental Practices: General Environmental Management - Investigating improved Wastewater Treatment Methods / Systems |
2016 |
Source Reduction:: W13: Improved maintenance scheduling, recordkeeping, or procedures[-0-4%]
Source Reduction:: W74: Improved application techniques[-5-14%] |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s) Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T03: Materials balance audits |
W13: Improved management of process solutions for plating and wastewater treatment. W74: Better control of scrap categorization for recycling. Source Reduction - GLSS Project team assignments Source Reduction - GLSS Team Assignments |
2015 |
Source Reduction:: W13: Improved maintenance scheduling, recordkeeping, or procedures
Source Reduction:: W74: Improved application techniques |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T04: Participative team management |
|
2014 |
Source Reduction:: W33: Installed overflow alarms or automatic shutoff valves[-100%]
Source Reduction:: W51: Instituted recirculation within a process[-100%] Source Reduction:: W58: Other process modifications[-50-99%] Source Reduction:: W15: Introduced an in-line product quality monitoring or other process analysis system[-100%] |
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T10: Vendor assistance Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management |
|
2013 |
Source Reduction:: W33: Installed overflow alarms or automatic shutoff valves
Source Reduction:: W51: Instituted recirculation within a process Source Reduction:: W58: Other process modifications Source Reduction:: W15: Introduced an in-line product quality monitoring or other process analysis system |
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T10: Vendor assistance Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management |
|
2012 |
Source Reduction:: W33: Installed overflow alarms or automatic shutoff valves
Source Reduction:: W51: Instituted recirculation within a process Source Reduction:: W58: Other process modifications Source Reduction:: W15: Introduced an in-line product quality monitoring or other process analysis system |
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T10: Vendor assistance Methods to Identify SR Opportunities: T04: Participative team management Methods to Identify SR Opportunities: T04: Participative team management |
W15: Implementation of Global Lean Six Sigma to identifiy improvement opprotunities with business. W33: Alarm and process installed to automatically prevent spills within our waste water treatment plant. W51: Reuse of our plating bath solutions. W58: Significant reduction in generation of copper heavy wastewater sludges through better process management and dropping out of metals. |
1993 |
Source Reduction:: W54: Instituted better controls on operating bulk containers to minimize discarding
|
Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program)
|
|
1992 |
Source Reduction:: W51: Instituted recirculation within a process
|
Methods to Identify SR Opportunities: T09: Trade association/industry technical assistance program
Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program) |
|
1991 |
Source Reduction:: W51: Instituted recirculation within a process
Source Reduction:: W52: Modified equipment, layout, or piping |
Methods to Identify SR Opportunities: T09: Trade association/industry technical assistance program
Methods to Identify SR Opportunities: T05: Employee recommendation (independent of a formal company program) Methods to Identify SR Opportunities: T09: Trade association/industry technical assistance program Methods to Identify SR Opportunities: T11: Other |
The Waste Management Hierarchy |
The waste management hierarchy established by the Pollution Prevention Act (PPA) guides waste generators toward the best options for managing wastes.
The preferred option is to prevent pollution at its source, but for waste that is generated, the preferred management methods are recycling, followed
by burning for energy recovery, treatment and, as a last resort, disposing of the waste.
|