Facility ID: 36426CNTNRHIGHW
Facility Name and Address: GEORGIA-PACIFIC BREWTON LLC 32224 HWY 31 S BREWTON, AL 36426 Parent Company: KOCH INDUSTRIES INC Industry: Paperboard Mills (322130) Chemical: Barium compounds (except for barium sulfate (CAS No. 7727-43-7)) |
|
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2017 |
Source Reduction:: W58: Other process modifications
|
Methods to Identify SR Opportunities: T11: Other
|
W58: Stopped burning bark. Source Reduction - Replaced bark burning power boiler with Natural gas and Source Reduction: Source Reduction - We no longer burn bark in our recovery boilers. This has caused a significant decrease in the amount of Barium released from the mill. |
2016 |
Source Reduction:: W58: Other process modifications
|
Methods to Identify SR Opportunities: T11: Other
|
W58: Modified Recovery Boiler 3 from bark burning to natural gas in April 2016. No longer burn bark at the mill. |
2015 |
Source Reduction:: W29: Other changes in inventory control
Source Reduction:: W58: Other process modifications |
Methods to Identify SR Opportunities: T04: Participative team management
Methods to Identify SR Opportunities: T04: Participative team management |
W29: The Mill is currently participating in a beneficial reuse program to help the Mill limit the amount of waste that goes into our onsite landfill. W58: Barium compounds are from naturally occuring wood sources. Paper mills use large quantities of wood, thus reporting is required. In 2016, the Mill ceased all bark firing in its boilers, so that will lead to a reduction in this pollutant. |
2014 |
Source Reduction:: W51: Instituted recirculation within a process
|
Methods to Identify SR Opportunities: T01: Internal pollution prevention opportunity audit(s)
|
W51: In February of 2015, the Mill began burning its wastewater treatment plant residuals in its boiler rather than applying to its landfill. This will result in a reduction of this pollutant. Other Environmental Practices: Waste Treatment - The Mill has decreased the amount of loading to its wastewater treatment system by raising awareness and capital projects. This will reduce the amount of wastewater treatment plant residuals. |