Facility ID: 44839THGLD300SP
Facility Name and Address: AKZO NOBEL COATINGS INC 300 SPROWL RD HURON, OH 44839 Parent Company: AKZO NOBEL NV Industry: Plastics Material and Resin Manufacturing (325211) Chemical: Ethylbenzene |
|
Reporting Year | Section 8.10: Newly Implemented Source Reduction Activity | Section 8.10: Methods to Identify Activity | Section 8.11: Optional Pollution Prevention Information* |
---|---|---|---|
2022 |
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - The site continues to recycle solvents for use on-site Other Environmental Practices: General Environmental Management - A high efficiency Regenerative Thermal Oxidizer was installed in 2015 to reduce stack emissions |
||
2021 |
Source Reduction - The site has instituted Zero Waste to Landfill for all hazardous and non-hazardous waste.The site has reduced the number of off-specification batches produced thus reducing overall waste
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - The site continues to recycle solvents for use on-site |
||
2020 |
Other Environmental Practices - The site has instituted Zero Waste to Landfill for all hazardous and non-hazardous waste
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - The site continues to recycle solvents for use on-site Other Environmental Practices: General Environmental Management - A high efficiency Regenerative Thermal Oxidizer was installed in 2015 to reduce stack emissions |
||
2019 |
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - Continue recycling of solvents for use on-site Other Environmental Practices: General Environmental Management - New high efficiency Regenerative Thermal Oxidizer installed in 2015 to reduce stack emissions |
||
2018 |
Barriers: B6-Barriers to P2 B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas
|
Barriers to P2: B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas - New Regenerative Thermal Oxidizer installed in 2015 to reduce stack emissions Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - Continue recycling of solvents for use on-site |
|
2017 |
Barriers: B6-Barriers to P2 B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas
|
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Other Environmental Practices: Recycling - Continue recycling of solvents for use on-site Barriers to P2: B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas - New Regenerative Thermal Oxidizer installed in 2015 to reduce emissions |
|
2016 |
Barriers: B6-Barriers to P2 B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas
|
Other Environmental Practices: Energy Recovery - Waste from the site is disposed of off-site using energy recovery processes Barriers to P2: B6 - Pollution prevention previously implemented - additional reduction does not appear technically or economically feas - A Regenerative Thermal Oxidizer was installed to reduce stack emissions in 2015. Other Environmental Practices: Recycling - Continue recycling of solvents for use on-site. |
|
2015 |
Source Reduction:: W29: Other changes in inventory control
|
Methods to Identify SR Opportunities: T11: Other
|
W29: Inventory on hand reductions - Maintaining lower inventory quantities on site. Other Environmental Practices: General Environmental Management - A Regenerative Thermal Oxidizer was installed to reduce stack emissions and was in use for full year 2015. Other Environmental Practices: Recycling - Continue recycling of solvents for use on-site. |
2014 |
Other Environmental Practices: General Environmental Management - A new Regenerative Thermal Oxidizer was installed in August of 2014 and will reduce stack air emissions |
The Waste Management Hierarchy |
The waste management hierarchy established by the Pollution Prevention Act (PPA) guides waste generators toward the best options for managing wastes.
The preferred option is to prevent pollution at its source, but for waste that is generated, the preferred management methods are recycling, followed
by burning for energy recovery, treatment and, as a last resort, disposing of the waste.
|