Skip to main content
We're sorry but Envirofacts is not intended to work with Internet Explorer. Please switch to Chrome/Edge/Firefox or any modern browser to continue.
U.S. flag

An official website of the United States government

Here's how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock ( Lock A locked padlock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

    • Environmental Topics
    • Air
    • Bed Bugs
    • Chemicals and Toxics
    • Climate Change
    • Emergency Response
    • Environmental Information by Location
    • Environmental Justice
    • Greener Living
    • Health
    • Land, Waste, and Cleanup
    • Lead
    • Mold
    • Pesticides
    • Radon
    • Science Topics
    • Water Topics
    • A-Z Topic Index
    • Laws & Regulations
    • By Business Sector
    • By Topic
    • Compliance
    • Enforcement
    • Guidance
    • Laws and Executive Orders
    • Regulations
    • Report a Violation
    • Environmental Violations
    • Fraud, Waste or Abuse
    • About EPA
    • Our Mission and What We Do
    • EPA Administrator
    • Headquarters Offices
    • Regional Offices
    • Labs and Research Centers
    • Planning, Budget, and Results
    • Organization Chart
    • EPA History
    • Staff Directory
Related Topics:
  • Envirofacts
Contact Us
Home | Multisystem Search | Topic Searches | System Data Searches | About the Data | Data Downloads | Widgets | Services | Mobile | Other Datasets
Go back

Under the Pollution Prevention Act of 1990 (PPA), TRI collects information to track industry progress in reducing waste generation and moving towards safer waste management alternatives. Measures that facilities have taken to prevent pollution and reduce the amount of toxic chemicals entering the environment are shown in the table below. Although factors other than these reported practices contribute to year-to-year changes in releases, results are sorted by largest reduction in order to facilitate identification of pollution prevention successes. View the to learn about this report's features.




Go To Bottom Of The Page

List of Facilities in TRI submitting Pollution Prevention Information for Selected Criteria:

Year: between 2016 and 2024
P2 Text Filters:
Year-to-Year Comparison:
TRI Facility ID Facility Name Address Chemical Name Industry Year Prior Year Release * Current Year Release * Percent Change Pollution Prevention Information (Activity Codes/Text/[Reduction]) P2 Report P2 Report URL
27317RRWNT200CO ARROW INTERNATIONAL INC (TELEFLEX INC) 312 COMMERCE PL,
ASHEBORO,
NC 27203
Ethylene oxide 339112: Surgical and Medical Instrument Manufacturing 2020 144.00 133.00 -7.64 Source Reduction: Ethylene oxide sterilization is required to meet FDA requirements. Arrow International, Inc. implemented the following waste reduction and elimination plan for 2020: 1. Used only 100% ethylene oxide as a sterilant. Ethylene oxide is oxidized, post-process to carbon dioxide and water. 2. Maximized the utilization of the sterilizers by designing product pallet stacking configurations using a software program specifically designed to volumetrically optimize product loading. 3. Product batches were built to completely fill each pallet and a full load of 8 pallets was run through each sterilization cycle to minimize the amount of ethylene oxide used and maximize efficiency. 4. The sterilization processes are designed and validated to use the lowest effective concentration of ethylene oxide necessary to sterilize our products. 5. Standard operating procedures for each sterilization cycle mandate test protocols designed to detect any leaks in the system prior to introduction of ethylene oxide into the sterilization chamber. Ethylene oxide is introduced to each cycle only after the test cycle is successfully complete for every cycle run. If a problem is detected, the cycle is aborted prior to the introduction of ethylene oxide into the chamber, reducing waste and eliminating any potential leakage due to equipment failure. //enviro.epa.gov/enviro/P2_EF_Query.p2_report?FacilityId=27317RRWNT200CO&ChemicalId=0000075218&ReportingYear=2020&DocCtrlNum=1320218616100&Opt=0
27317RRWNT200CO ARROW INTERNATIONAL INC (TELEFLEX INC) 312 COMMERCE PL,
ASHEBORO,
NC 27203
Ethylene oxide 339112: Surgical and Medical Instrument Manufacturing 2021 133.00 123.00 -7.52 Source Reduction: Source Reduction - Ethylene oxide sterilization is required to meet FDA requirements. Arrow International, Inc. implemented the following waste reduction and elimination plan for 2021: 1. Used only 100% ethylene oxide as a sterilant. Ethylene oxide is oxidized, post-process to carbon dioxide and water. 2. Maximized the utilization of the sterilizers by designing product pallet stacking configurations using a software program specifically designed to volumetrically optimize product loading. 3. Product batches were built to completely fill each pallet and a full load of 8 pallets was run through each sterilization cycle to minimize the amount of ethylene oxide used and maximize efficiency. 4. The sterilization processes are designed and validated to use the lowest effective concentration of ethylene oxide necessary to sterilize our products. 5. Standard operating procedures for each sterilization cycle mandate test protocols designed to detect any leaks in the system prior to introduction of ethylene oxide into the sterilization chamber. Ethylene oxide is introduced to each cycle only after the test cycle is successfully complete for every cycle run. If a problem is detected, the cycle is aborted prior to the introduction of ethylene oxide into the chamber, reducing waste and eliminating any potential leakage due to equipment failure. //enviro.epa.gov/enviro/P2_EF_Query.p2_report?FacilityId=27317RRWNT200CO&ChemicalId=0000075218&ReportingYear=2021&DocCtrlNum=1321219582513&Opt=0
27317RRWNT200CO ARROW INTERNATIONAL INC (TELEFLEX INC) 312 COMMERCE PL,
ASHEBORO,
NC 27203
Ethylene oxide 339112: Surgical and Medical Instrument Manufacturing 2019 140.00 144.00 2.86 Source Reduction: Ethylene oxide sterilization is required to meet FDA requirements. Arrow International, Inc. implemented the following waste reduction and elimination plan for 2019: 1. Used only 100% ethylene oxide as a sterilant. Ethylene oxide is oxidized, post-process tocarbon dioxide and water. 2. Maximized the utilization of the sterilizers by designing product pallet stacking configurations using a software program specifically designed to volumetrically optimize product loading. 3. Product batches were built to completelyfill each pallet and a full load of 8 pallets was run through each sterilization cycle to minimize the amount of ethylene oxide used and maximize efficiency. 4. The sterilization processes are designed and validated to use the lowest effective concentration of ethylene oxide necessary to sterilize our products. 5. Standard operating procedures for each sterilization cycle mandate test protocols designed to detect any leaks in the system prior to introduction of ethylene oxide into the sterilization chamber. Ethylene oxide is introduced to each cycle only after the test cycle is successfully complete for every cycle run. If a problem is detected, the cycle is aborted prior to the introduction of ethylene oxide into the chamber, reducing waste and eliminating any potential leakage due to equipment failure. //enviro.epa.gov/enviro/P2_EF_Query.p2_report?FacilityId=27317RRWNT200CO&ChemicalId=0000075218&ReportingYear=2019&DocCtrlNum=1319217658867&Opt=0


* - Dioxin releases are in grams; all others in pounds
  • Assistance
  • Spanish
  • Arabic
  • Chinese (simplified)
  • Chinese (traditional)
  • French
  • Haitian Creole
  • Korean
  • Portuguese
  • Russian
  • Tagalog
  • Vietnamese
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshot
  • Grants
  • No FEAR Act Data
  • Plain Writing
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions
  • Site Feedback

Follow.