PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 95-63-6 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: 1,2,4-Trimethylbenzene
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: YES |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: NO |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
257 |
Pounds |
O - Other Approaches |
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
4076 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
NO DATA |
|
NO DATA |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
NA |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
2615 |
Pounds |
C - Mass Balance Calculations |
M56 - Energy Recovery |
2 |
4894 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
4523 |
4333 |
4116 |
7409 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
3896 |
2615 |
2484 |
4471 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
NA |
4894 |
4649 |
8368 |
8.6 |
Quantity Treated Onsite |
Pounds |
19279 |
10143 |
9636 |
17345 |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T09 - TRADE ASSOCIATION/INDUSTRY TECHNICAL ASSISTANCE PROGRAM |
|||
W58 - OTHER PROCESS MODIFICATIONS |
T04 - PARTICIPATIVE TEAM MANAGEMENT |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 100-41-4 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Ethylbenzene
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: YES |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
444 |
Pounds |
O - Other Approaches |
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
404 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
NO DATA |
|
NO DATA |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
NA |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
3725 |
Pounds |
O - Other Approaches |
M56 - Energy Recovery |
2 |
6892 |
Pounds |
O - Other Approaches |
M20 - Solvents/Organics Recovery |
2 RCRA Number: SCD981031040 | Parent Company Controlled: NO |
Name: SAFETY-KLEEN CORP. | Address: 2818 OLD WOODRUFF ROAD |
City: GREER | State: SC |
County: SPARTANBURG | Zip Code: 29651 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
79 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
3755 |
848 |
806 |
1451 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
25059 |
3725 |
3539 |
6550 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
0 |
6971 |
6622 |
11920 |
8.6 |
Quantity Treated Onsite |
Pounds |
15878 |
1722 |
1636 |
2945 |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T09 - TRADE ASSOCIATION/INDUSTRY TECHNICAL ASSISTANCE PROGRAM |
|||
W58 - OTHER PROCESS MODIFICATIONS |
T04 - PARTICIPATIVE TEAM MANAGEMENT |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 108-10-1 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Methyl isobutyl ketone
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
2644 |
Pounds |
O - Other Approaches |
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
1347 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
NO DATA |
|
NO DATA |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
NA |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
20544 |
Pounds |
C - Mass Balance Calculations |
M56 - Energy Recovery |
2 |
38242 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
2 RCRA Number: SCD981031040 | Parent Company Controlled: NO |
Name: SAFETY-KLEEN CORP. | Address: 2818 OLD WOODRUFF ROAD |
City: GREER | State: SC |
County: SPARTANBURG | Zip Code: 29651 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
197 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
18940 |
3991 |
3791 |
6824 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
70141 |
20544 |
19517 |
35131 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
0 |
38439 |
36517 |
65731 |
8.6 |
Quantity Treated Onsite |
Pounds |
35282 |
12596 |
11966 |
21539 |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T09 - TRADE ASSOCIATION/INDUSTRY TECHNICAL ASSISTANCE PROGRAM |
|||
W58 - OTHER PROCESS MODIFICATIONS |
T04 - PARTICIPATIVE TEAM MANAGEMENT |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: N230 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Certain glycol ethers
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: YES |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 10000 to 99999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
252 |
Pounds |
O - Other Approaches |
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
30073 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
75616 |
Pounds |
O - Other Approaches |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
GREER COMMISSION OF PUBLIC WOR KS |
301 MCCALL STREET |
GREER |
SC |
SPARTANBURG |
29650 |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
13375 |
Pounds |
O - Other Approaches |
M56 - Energy Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
30625 |
30325 |
28809 |
51856 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
21229 |
13375 |
12706 |
22871 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
0 |
0 |
0 |
0 |
8.6 |
Quantity Treated Onsite |
Pounds |
59040 |
30372 |
28853 |
51935 |
8.7 |
Quantity Treated Offsite |
Pounds |
72207 |
75616 |
71835 |
129303 |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T09 - TRADE ASSOCIATION/INDUSTRY TECHNICAL ASSISTANCE PROGRAM |
|||
W58 - OTHER PROCESS MODIFICATIONS |
T04 - PARTICIPATIVE TEAM MANAGEMENT |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 872-50-4 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: N-Methyl-2-pyrrolidone
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: NO |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
5662 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
6109 |
Pounds |
O - Other Approaches |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
GREER COMMISSION OF PUBLIC WOR KS |
301 MCCALL STREET |
GREER |
SC |
SPARTANBURG |
29650 |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
348 |
Pounds |
O - Other Approaches |
M56 - Energy Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
5494 |
5662 |
5379 |
9682 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
4233 |
348 |
331 |
596 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
0 |
0 |
0 |
0 |
8.6 |
Quantity Treated Onsite |
Pounds |
6116 |
NA |
NA |
NA |
8.7 |
Quantity Treated Offsite |
Pounds |
NA |
6109 |
5804 |
10447 |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
NA |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 1330-20-7 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Xylene (mixed isomers)
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: YES |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
4536 |
Pounds |
O - Other Approaches |
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
1783 |
Pounds |
O - Other Approaches |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
NO DATA |
|
NO DATA |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
NA |
6.2 Transfers to other Off-Site Locations
1 RCRA Number: SCD036275626 | Parent Company Controlled: NO |
Name: SOUTHEASTERN CHEMICAL AND SOLV ENT | Address: 755 INDUSTRIAL ROAD |
City: SUMTER | State: SC |
County: SUMTER | Zip Code: 29150 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
16511 |
Pounds |
C - Mass Balance Calculations |
M56 - Energy Recovery |
2 |
30716 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
2 RCRA Number: SCD981031040 | Parent Company Controlled: NO |
Name: SAFETY-KLEEN CORP. | Address: 2818 OLD WOODRUFF ROAD |
City: GREER | State: SC |
County: SPARTANBURG | Zip Code: 29651 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
177 |
Pounds |
C - Mass Balance Calculations |
M20 - Solvents/Organics Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: GASEOUS |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
P21 - ADSORPTION -- CARBON |
2 |
F71 - FUME/VAPOR |
3 |
NA |
7A.1c. Range of Influent Concentration: 1 PPM TO 100 PPM |
7A.1d. Waste Treatment Efficiency Estimate: .94 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
12255 |
6319 |
6003 |
10805 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
Pounds |
70900 |
16511 |
15685 |
28233 |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
0 |
30893 |
29348 |
52826 |
8.6 |
Quantity Treated Onsite |
Pounds |
48487 |
9907 |
9412 |
16942 |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T09 - TRADE ASSOCIATION/INDUSTRY TECHNICAL ASSISTANCE PROGRAM |
|||
W58 - OTHER PROCESS MODIFICATIONS |
T04 - PARTICIPATIVE TEAM MANAGEMENT |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 7664-38-2 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Phosphoric acid
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
NO |
22 |
Pounds |
C - Mass Balance Calculations |
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
NO DATA |
|
NO DATA |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
NA |
6.2 Transfers to other Off-Site Locations
RCRA Number: | Parent Company Controlled: |
Name: | Address: |
City: | State: |
County: | Zip Code: |
Country Code (Non - US): | Province: |
TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|
NO DATA |
|
NO DATA |
NO DATA |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: WASTEWATER |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
C11 - NEUTRALIZATION |
2 |
NA |
7A.1c. Range of Influent Concentration: GREATER THAN 1 PERCENT |
7A.1d. Waste Treatment Efficiency Estimate: 100 |
7A.1e. Based on Operating Data?: YES |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
Pounds |
0 |
22 |
21 |
38 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
|
NA |
NA |
NA |
NA |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
|
NA |
NA |
NA |
NA |
8.6 |
Quantity Treated Onsite |
Pounds |
30331 |
24630 |
23399 |
42118 |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
NA |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
PART I. FACILITY IDENTIFICATION INFORMATION (FORM A)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
No Data |
No Data |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 0000107211
1.2 Toxic Chemical or Chemical Category Name: Ethylene glycol
1.3 Generic Chemical Name: NA
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 1998
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
GUENTER KLAMER |
VICE PRESIDENT |
None |
30-JUN-99 |
Section 4. Facility Identification
TRI Facility ID: 29651BMWMN1400H
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
BMW MANUFACTURING CO LLC |
1400 HWY 101 S |
GREER |
SPARTANBURG |
SC |
29651 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
BMW MANUFACTURING CO LLC |
POST OFFICE BOX 11000 |
SPARTANBURG |
SC |
29304 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
No Data |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
BOBBY HITT |
8649895536 |
4.5 SIC Codes
SIC CODE | PRIMARY | SIC CODE DESCRIPTION |
---|---|---|
3711 |
YES |
MOTOR VEHICLES AND CAR BODIES |
NA |
NO |
NA |
4.6 Location
LATITUDE | LONGITUDE |
---|---|
034-53-40 |
082-10-30 |
4.7 Dun Numbers
DUNS NUMBER |
---|
797398195 |
4.8 RCRA ID Numbers
RCRA ID NUMBER |
---|
NO DATA |
4.9 NPDES Permit Numbers
NPDES PERMIT NUMBER |
---|
NO DATA |
4.10 Underground Injection Well Code (UIC) ID Number
UIC ID NUMBER |
---|
NO DATA |
5. Parent Company Information
Parent Company Name: No US Parent Company
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 7632-00-0 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Sodium nitrite
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: YES |
Ancillary or Other Use: NO |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 1000 to 9999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
NO |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3 Surface Impoundment
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs) 6.1.A Total Quantity Transferred to POTWs and Basis of Estimate
6.1.A. | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
1 |
2979 |
Pounds |
O - Other Approaches |
6.1.B POTW Locations
6.1.B. | POTW NAME | ADDRESS | CITY | STATE | COUNTY | ZIP CODE |
---|---|---|---|---|---|---|
1 |
GREER COMMISSION OF PUBLIC WORKS |
301 MCCALL ST. |
GREER |
SC |
GREENVILLE |
29650 |
6.2 Transfers to other Off-Site Locations
RCRA Number: | Parent Company Controlled: |
Name: | Address: |
City: | State: |
County: | Zip Code: |
Country Code (Non - US): | Province: |
TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|
NO DATA |
|
NO DATA |
NO DATA |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: WASTEWATER |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
C46 - GENERAL OXIDATION (INCLUDING DISINFECTION) -- OTHER |
2 |
NA |
7A.1c. Range of Influent Concentration: 100 PPM TO 1 PERCENT |
7A.1d. Waste Treatment Efficiency Estimate: 75.24 |
7A.1e. Based on Operating Data?: NO |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1 |
Quantity Released |
|
NA |
NA |
NA |
NA |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
|
NA |
NA |
NA |
NA |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
|
NA |
NA |
NA |
NA |
8.6 |
Quantity Treated Onsite |
Pounds |
NA |
9052 |
8599 |
15478 |
8.7 |
Quantity Treated Offsite |
Pounds |
11383 |
2979 |
2830 |
5094 |
8.8 One-Time Event Release: 0 Pounds
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
NA |
8.11 Additional Data Indicator: NO
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities