Reference Point/Description | Latitude | Longitude | Collection Method | Accuracy Value |
---|---|---|---|---|
ENTRANCE POINT OF A FACILITY OR STATION | 32.892887 | -96.89538 | ADDRESS MATCHING-HOUSE NUMBER | 50 |
RCRA ID NUMBER |
---|
TXR000081283 |
NPDES PERMIT NUMBER |
---|
TXRNEAU48 |
TXRNEBM74 |
UIC ID NUMBER |
---|
NO DATA |
To correct the FRS latitude, longitude or program ID values click on the "Report an Error" button in the top right corner of this page. Facilities wishing to correct other data elements with the FORM R or FORM A should refer to the related TRI-MEweb tutorial.. |
For more information, see Collection of Latitude, Longitude and Program ID Data Has Been Discontinued. |
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 2013
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
ANDREW PETTY |
MANAGER, ENVIRONMENTAL, SAFETY AND HEALTH |
Electronic |
12-JUN-14 |
Section 4. Facility Identification
TRI Facility ID: 75203LXTTC2465J
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
LUXOTTICA OPTICAL MANUFACTURING N.A. DALLAS |
2465 JOE FIELD RD |
DALLAS |
DALLAS |
TX |
75229 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
LUXOTTICA OPTICAL MANUFACTURING N.A. DALLAS |
2465 JOE FIELD RD |
DALLAS |
TX |
75229 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
NO |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
ANDREW PETTY |
5137656909 |
4.5 NAICS Codes
NAICS CODE | PRIMARY | NAICS CODE DESCRIPTION |
---|---|---|
339115 |
YES |
Ophthalmic Goods Manufacturing |
4.7 Dun Numbers
DUNS NUMBER |
---|
780006248 |
5. Parent Company Information
Parent Company Name: LUXOTTICA RETAIL N.A.
Parent Company DUNS Number: 141583190
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 7440-43-9 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Cadmium
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: NO |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 100 to 999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
YES |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3A RCRA Subtitle C Surface Impoundments
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3B Other Surface Impoundments
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs)
1 - NAME: CENTRAL WASTEWATER TREATMENT PLANT | ADDRESS: 1020 SAGENT ROAD |
CITY: DALLAS | STATE: TX |
COUNTY: DALLAS | ZIP CODE: 75203 |
TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|
21 |
Pounds |
M2 - Monitoring, Periodic/Random |
6.2 Transfers to other Off-Site Locations
2 RCRA Number: NA | Parent Company Controlled: NO |
Name: 5NPLUS WISCONSIN CORP. | Address: 6474 BLANCHAR'S CROSSING |
City: WINDSOR | State: WI |
County: DANE | Zip Code: 53598 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
22 |
Pounds |
M2 - Monitoring, Periodic/Random |
M24 - Metals Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: WASTEWATER |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
H077 - Other chemical precipitation with or without pre-treatment |
7A.1d. Waste Treatment Efficiency Estimate: Greater than 50% but less than or equal to 95% |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1a |
Total on-site disposal to Class I Underground Injection Wells, RCRA Subtitle C landfills, and other landfills |
|
NA |
NA |
NA |
NA |
8.1b |
Total other on-site disposal or other releases |
|
NA |
NA |
NA |
NA |
8.1c |
Total off-site disposal to Class I Underground Injection Wells, RCRA Subtitle C landfills, and other landfills |
Pounds |
0 |
0 |
NA |
NA |
8.1d |
Total other off-site disposal or other releases |
Pounds |
5 |
21 |
5 |
5 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
|
NA |
NA |
NA |
NA |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
22 |
22 |
60 |
60 |
8.6 |
Quantity Treated Onsite |
|
NA |
NA |
NA |
NA |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: NA
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W15 - INTRODUCED AN IN-LINE PRODUCT QUALITY MONITORING OR OTHER PROCESS ANALYSIS SYSTEM |
T01 - INTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
|||
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T02 - EXTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
|||
W50 - OPTIMIZED REACTION CONDITIONS OR OTHERWISE INCREASED EFFICIENCY OF SYNTHESIS |
T01 - INTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
8.11 Additional Data Indicator: YES
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
Wasteater treatment process improvements made in 2013 include corrected metals removal treatment on alloy tank wastewater, improved sediment retention on alloy tank wastewater treatment drums and pilot metals removal and filtration system proposed for all cadmium-contacting wastewater|W15:Alloy tank wastewater treatment container modifications to increase sediment retention.|T01:Post NOV wastewater treatment audit|W13:Metals removal alloy tank wastewater treatment process performed to exact specifications|T02:Wastewater district effluent testing program identified high cadmium concentrationsWastewater treatment logging and work instructions|W50:Pilot metals removal wastewater treatment project in 2014 capital planning for treatment and filtration of all cadmium-contacting wastewater|T01:Post NOV wastewater treatment audit |
9.1 Miscellaneous, Additional or Optional Information regarding the Form R submission
Metal alloy reclaim shipments were reduced by nearly 50% in 2013 - reducing amounts of cadmium metals recycled off-site. Wastewater treatment processes required internal auditing and multiple improvements due to 2013 wastewater district testing results showing above-Permit limit levels of total cadmium. Wastewater treatment practices to specifications, wastewater treatment drum modifications and enhanced wastewater treatment tank clean-outs were implemented.|PRAI:10% YOY reduction in overall optical lab lens processing jobs in 2013. |
PART I. FACILITY IDENTIFICATION INFORMATION (FORM R)
Reporting Year: 2013
Section 2. Trade Secret Information
2.1 Trade Secret: NO
2.2 Sanitized Copy: Unsanitized
Section 3. Certification
CERTIFYING OFFICIAL'S NAME | CERTIFYING OFFICIAL'S TITLE | CERTIFYING OFFICIAL'S SIGNATURE | DATE SIGNED |
---|---|---|---|
ANDREW PETTY |
MANAGER, ENVIRONMENTAL, SAFETY AND HEALTH |
Electronic |
12-JUN-14 |
Section 4. Facility Identification
TRI Facility ID: 75203LXTTC2465J
4.1 Facility Name and Address.
Facility Information
NAME | STREET | CITY | COUNTY | STATE | ZIP CODE |
---|---|---|---|---|---|
LUXOTTICA OPTICAL MANUFACTURING N.A. DALLAS |
2465 JOE FIELD RD |
DALLAS |
DALLAS |
TX |
75229 |
BIA Tribal Code | Tribe |
---|---|
NO DATA |
NO DATA |
Mailing Information
NAME | STREET | CITY | STATE | ZIP CODE |
---|---|---|---|---|
LUXOTTICA OPTICAL MANUFACTURING N.A. DALLAS |
2465 JOE FIELD RD |
DALLAS |
TX |
75229 |
PROVINCE | COUNTRY (NON - US) |
---|---|
NO DATA |
NO DATA |
4.2 Facility Classification
ENTIRE FACILITY | PARTIAL FACILITY | FEDERAL FACILITY | GOCO FACILITY |
---|---|---|---|
YES |
NO |
NO |
NO |
4.3 Technical Contact
Not Available to the Public as this information is only for Intranet.
4.4 Public Contact
NAME | PHONE |
---|---|
ANDREW PETTY |
5137656909 |
4.5 NAICS Codes
NAICS CODE | PRIMARY | NAICS CODE DESCRIPTION |
---|---|---|
339115 |
YES |
Ophthalmic Goods Manufacturing |
4.7 Dun Numbers
DUNS NUMBER |
---|
780006248 |
5. Parent Company Information
Parent Company Name: LUXOTTICA RETAIL N.A.
Parent Company DUNS Number: 141583190
PART II. CHEMICAL - SPECIFIC INFORMATION
1.1 CAS Number: 7439-92-1 PFAS Indicator: NO
1.2 Toxic Chemical or Chemical Category Name: Lead
1.3 Generic Chemical Name: NA
1.4 Distribution of Each Member of the Dioxin and Dioxin like Compounds Category
NA | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NO |
Section 2. Mixture Component Identity
2.1 Supplier Provided Generic Chemical Name: NA
Section 3. Activities and Uses of the Toxic Chemical
3.1 Manufacture the Toxic Chemical:
Produce: NO | Import: NO | On-Site Use/Processing: NO |
Sale/Distribution: NO | Byproduct: NO | Impurity: NO |
3.2 Process the Toxic Chemical:
Reactant: NO |
Formulation Component: NO |
Article Component: NO |
Repackaging: NO |
Impurity: NO |
Recycling: |
3.3 Otherwise Use the Toxic Chemical:
Chemical Processing Aid: NO |
Manufacturing Aid: NO |
Ancillary or Other Use: YES |
Section 4. Maximum Amount of the Toxic Chemical Onsite During the Calendar Year
Maximum Chemical Amount: 100 to 999
Section 5. Quantity of the Toxic Chemical Entering each Environmental Medium Onsite
5.1 Fugitive or Non-Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.2 Stack or Point Air Emissions
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.3 Discharges to Receiving Streams or Water Bodies
NA | STREAM/WATER BODY NAME | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | % FROM STORMWATER |
---|---|---|---|---|---|
YES |
NA |
|
|
5.4-5.5 Disposal to Land Onsite
5.4.1 Underground Injection Onsite to Class I Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.4.2 Underground Injection Onsite to Class II-V Wells.
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5 Disposal to Land Onsite
5.5.1A RCRA Subtitle C Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.1B Other Landfills
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.2 Land Treatment/Application Farming
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3A RCRA Subtitle C Surface Impoundments
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.3B Other Surface Impoundments
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
5.5.4 Other Disposal
NA | TOTAL RELEASE (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|---|
YES |
|
|
Section 6. Transfers of the Toxic Chemical in Wastes to Off-Site Locations
6.1 Discharges to Publicly Owned Treatment Works (POTWs)
1 - NAME: CENTRAL WASTEWATER TREATMENT PLANT | ADDRESS: 1020 SAGENT ROAD |
CITY: DALLAS | STATE: TX |
COUNTY: DALLAS | ZIP CODE: 75203 |
TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE |
---|---|---|
21 |
Pounds |
M2 - Monitoring, Periodic/Random |
6.2 Transfers to other Off-Site Locations
2 RCRA Number: NA | Parent Company Controlled: NO |
Name: 5NPLUS WISCONSIN CORP. | Address: 6474 BLANCHAR'S CROSSING |
City: WINDSOR | State: WI |
County: DANE | Zip Code: 53598 |
Country Code (Non - US): | Province: |
OFFSITE AMOUNT SEQUENCE | TOTAL TRANSFERS (per year) | UNIT OF MEASURE | BASIS OF ESTIMATE | WASTE MANAGEMENT TYPE |
---|---|---|---|---|
1 |
94 |
Pounds |
M2 - Monitoring, Periodic/Random |
M24 - Metals Recovery |
Section 7A. On-Site Waste Treatment Methods and Efficiency
7A.1a. Waste Stream: WASTEWATER |
7A.1b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
H071 - Chemical reduction with or without precipitation |
7A.1d. Waste Treatment Efficiency Estimate: Greater than 95% but less than or equal to 99% |
7A.2a. Waste Stream: WASTEWATER |
7A.2b. |
WASTE TREATMENT METHOD(S) SEQUENCE |
---|---|
1 |
H077 - Other chemical precipitation with or without pre-treatment |
7A.2d. Waste Treatment Efficiency Estimate: Greater than 95% but less than or equal to 99% |
Section 7B. On-Site Energy Recovery Processes
ON SITE ENERGY RECOVERY PROCESSES |
---|
NA |
Section 7C. On-Site Recycling Processes
ON SITE RECYCLING PROCESSES |
---|
NA |
Section 8. Source Reduction and Recycling Activities
SECTION |
TYPE OF QUANTITY | UNITS | PRIOR YEAR | CURRENT REPORTING YEAR | FOLLOWING YEAR | SECOND FOLLOWING YEAR |
---|---|---|---|---|---|---|
8.1a |
Total on-site disposal to Class I Underground Injection Wells, RCRA Subtitle C landfills, and other landfills |
|
NA |
NA |
NA |
NA |
8.1b |
Total other on-site disposal or other releases |
|
NA |
NA |
NA |
NA |
8.1c |
Total off-site disposal to Class I Underground Injection Wells, RCRA Subtitle C landfills, and other landfills |
Pounds |
0 |
0 |
NA |
NA |
8.1d |
Total other off-site disposal or other releases |
Pounds |
10 |
21 |
8 |
8 |
8.2 |
Quantity Used for Energy Recovery Onsite |
|
NA |
NA |
NA |
NA |
8.3 |
Quantity Used for Energy Recovery Offsite |
|
NA |
NA |
NA |
NA |
8.4 |
Quantity Recycled Onsite |
|
NA |
NA |
NA |
NA |
8.5 |
Quantity Recycled Offsite |
Pounds |
177 |
94 |
150 |
125 |
8.6 |
Quantity Treated Onsite |
|
NA |
NA |
NA |
NA |
8.7 |
Quantity Treated Offsite |
|
NA |
NA |
NA |
NA |
8.8 One-Time Event Release: NA
8.9 Production Ratio: .9
8.10 Source Reduction Activities
SOURCE REDUCTION ACTIVITIES | METHOD 1 | METHOD 2 | METHOD 3 | ESTIMATED ANNUAL REDUCTION |
---|---|---|---|---|
W52 - MODIFIED EQUIPMENT, LAYOUT, OR PIPING |
T01 - INTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
|||
W13 - IMPROVED MAINTENANCE SCHEDULING, RECORDKEEPING, OR PROCEDURES |
T01 - INTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
|||
W15 - INTRODUCED AN IN-LINE PRODUCT QUALITY MONITORING OR OTHER PROCESS ANALYSIS SYSTEM |
T01 - INTERNAL POLLUTION PREVENTION OPPORTUNITY AUDIT(S) |
8.11 Additional Data Indicator: YES
Additional Optional Information on Source Reduction, Recycling, or Pollution Control Activities
Wastewater effluent testing identified high cadmium concentration resulting in improvements to wastewater metals removal treatment procedures, modifications to wastewater treatment drums to control sediments releases and pilot wastewater treatment programs for all lead-contacting wastewaters.|T01:Alloy tank wastewater treatment logs are used to document daily treatments |